F1/F2 spreads: what face-left and face-right readings tell a reviewer
A total station observes each target on both faces: face left (F1) and face right (F2). The difference between the two readings, the spread, is one of the quickest checks on an instrument and its setup. This guide explains what a spread measures, works through a synthetic example, and lists what to look at when a reduction report flags one. SurveyMarkup's Report Reader surfaces spread lines as advisory prompts; the surveyor decides what they mean.
By Tim Albash, engineering surveyor · Updated
Advisory and unverified — not for survey deliverables. A registered surveyor must confirm any output before it is relied on.
Face left and face right
On face left the vertical circle sits to the observer's left. Transit the telescope, turn the instrument through 180° and observe the same target again: that is face right. For a horizontal direction, the face-right reading should be the face-left reading plus or minus 180°. For a zenith angle, the two readings should add up to 360°.
What the spread measures
Take 180° off the face-right reading and compare it with face left. The difference is the spread:
F2′ = F2 ± 180°
spread = F1 − F2′ ≈ 2c on a horizontal sight
mean direction = (F1 + F2′) ÷ 2
index error i = (Z1 + Z2 − 360°) ÷ 2
mean zenith angle = (Z1 − Z2 + 360°) ÷ 2
Most of a steady spread is horizontal collimation error, c: a line of sight that isn't quite at right angles to the trunnion axis. It has opposite signs on the two faces, so it doubles in the spread and cancels in the mean. Trunnion-axis error, whose effect grows on steep sights, also cancels in the mean of faces, and so does the vertical index error on zenith angles.
Pointing and centring errors, a vertical axis that isn't truly vertical, and a target that moved do not cancel. They stay in the mean, so a spread is worth reading, not just averaging away.
Worked example with synthetic readings
Two rounds of horizontal directions to one target, then one zenith-angle pair. The readings are synthetic: made up for this example, not taken from an instrument or a job.
| Reading | Round 1 | Round 2 |
|---|---|---|
| F1 | 045°12′20″ | 045°12′24″ |
| F2 | 225°12′30″ | 225°12′32″ |
| F2′ = F2 − 180° | 045°12′30″ | 045°12′32″ |
| Spread F1 − F2′ | −10″ | −8″ |
| Mean | 045°12′25″ | 045°12′28″ |
Both rounds put F2′ above F1 by a similar amount, 10″ and 8″. A steady spread like that points to collimation of about 4″ to 5″ on this sight, which the means remove. The round means differ by 3″; that agreement between rounds says more about the pointing and reading than the face spread does.
The zenith angles to the same target were Z1 = 88°45′10″ and Z2 = 271°14′40″. They add up to 359°59′50″, so the index error is (359°59′50″ − 360°) ÷ 2 = −5″ and the mean zenith angle is 88°45′15″.
Reading spread lines in a reduction report
Reduction reports list a spread per target, and often the spread between rounds as well. Check the report's legend for its sign convention and for the limit that set off any flag, then compare that limit with your field specification. Then read the pattern:
- A similar spread on every target at similar vertical angles: systematic collimation. The means are sound; if the spread is large against the instrument's specification, book a calibration check.
- A spread that grows on steep sights: look at trunnion-axis error and at how well the instrument was levelled.
- One target with a much larger spread than the rest: a pointing error, the wrong target, a prism that moved or a bumped tripod. Observe it again.
- Spreads that drift through the set: the instrument may have settled or warmed up. Check the backsight before trusting later rounds.
What a small spread doesn't show
A clean spread says the instrument read both faces consistently. It says nothing about whether the setup was right: an instrument over the wrong mark, a wrong instrument or target height, or a backsight to the wrong point all give tidy spreads and wrong coordinates. Check the mark, the heights and the backsight separately. For a free station, the free-station tool computes the station and orientation from two known control points, with residuals: a separate check on where the instrument stood.
How SurveyMarkup surfaces them
Report Reader pulls spread and tolerance lines from .rpt and .txt reports into a summary, with references back to the source lines. It points at lines worth a second look; it doesn't decide whether a set is acceptable. That stays with the surveyor.
Free tools for this check
Related next steps
Advisory and unverified — not for survey deliverables. A registered surveyor must confirm any output before it is relied on.