Skip to main content

Least squares adjustment for total-station control.

Merge Trimble JobXML and 12d .fld files exported from Trimble Access, run and test the control network adjustment, report PU and RU, and write adjusted coordinates into a copy of your own control CSV.

PRICE
A$495 once
PCS
2 per user
OFFLINE
Up to 44 days
GST
Not charged

Tested on local-grid jobs. MGA2020 jobs are supported but not yet checked on a real export; pilot firms help close this.

64-bit Windows 10 (1809 or later) or 11 · 2 PCs · internet at least every 44 days

Not on sale yet. Sales open after the pilot round; pilot firms run it on a real job with me first. Pilot firms get a free ControlAdjust licence for 3 months: no card, no automatic charge and no obligation to buy.

Advisory software: it flags items for your registered surveyor to review. It doesn't sign off survey work.

Plot · free pointsControlAdjust 0.2.0
Close-up of the free points in the SYN-2 exampleThe four free points SYN TA 1000 to 4000, labelled by number, between fixed marks PM1 and PM2, with 95 % error ellipses drawn ×2000 actual size. The largest semi-axis is 4.6 mm, at SYN TA 4000.PM1PM21000200030004000GRID NELLIPSES ×2000Error ellipses at 95 %
  • Fixed control · 9
  • Free · 4
  • 95 % ellipse ×2000
  • 1000–4000 = SYN TA 1000–4000

Network plot · SYN-2 example

Plot · SYN-2 exampleControlAdjust 0.2.0
Network plot of the SYN-2 examplePlan of 13 points: 9 fixed control marks drawn as triangles, 4 free points (SYN TA 1000 to 4000) drawn as circles, with 95 % error ellipses drawn ×2000 actual size. The largest semi-axis is 4.6 mm, at SYN TA 4000.B101B102B103B104B105B106B107PM1PM2SYN TA 1000SYN TA 2000SYN TA 3000SYN TA 4000GRID N25 mELLIPSES ×2000Error ellipses at 95 %
  • Fixed control · 9
  • Free · 4
  • 95 % ellipse ×2000
ControlAdjust output on the synthetic SYN-2 example network (no client data), redrawn for the web. ControlAdjust 0.2.0, run 5 Oct 2026.

Inputs

Trimble and 12d files in, one network out.

Load Trimble JobXML and 12d .fld files exported from Trimble Access together. ControlAdjust merges them into one observation set and takes your control CSV as fixed control.

.fld files carry no coordinate system, so ControlAdjust reads them on a local grid at scale factor 1 and can't self-check them. For an MGA job, enter the job's combined scale factor in Settings. Shots coded STK are treated as set-out and left out.

Reads: Trimble JobXML schema 5.x to 6.34 · 12d .fld

Trimble JobXML · 6.34SYN-2.jxl8 setups · 75 shots
12d field file · v6.0SYN-2.fld7 setups · 75 shots
MERGE
One observation set84 observations21 unknowns · 63 degrees of freedom
+ FIXED CONTROL
Control CSVREFSYN-2_CONTROL.csv10 points · 9 observed, held fixed
Inputs of the synthetic SYN-2 example (no client data). The two field files merge into one observation set; the control CSV comes in as fixed control.

Adjustment

Two tests your senior surveyor already knows.

The chi-square global test asks whether the network as a whole fits the precision you set. The Baarda w-test looks at each observation the rest of the network checks: anything outside the critical value (3.29 by default; you can change it in Settings) is flagged so you can review it before it bends the network. The decision on what to do with it stays with your surveyor. Observations you switch off, and ones nothing else checks, get no w-test; the report lists the unchecked ones.

  • OKwithin the critical value
  • FAILoutside the critical value; review this observation
  • REFfixed control from your CSV
w-tests · SYN-2 exampleControlAdjust 0.2.0

Global test within bounds · error factor 1.04 · 0 of 84 outside 3.29

Largest w-tests of 84 in the SYN-2 example run
ObswFinding
PM1 07:04 → B104+3.07OK
PM1 10:29 → B105−2.12OK
PM1 10:29·2 → B105−1.90OK
PM1 10:29 → B103+1.83OK
SYN TA 4000 → B105+1.81OK
The five largest of 84 w-tests in the synthetic SYN-2 example (no client data). None is outside 3.29, so every row reads OK.

Reports

A report your senior surveyor can read.

Positional uncertainty for each station and relative uncertainty between station pairs, computed with the ICSM SP1 formulas, with the global test and every w-test listed. With control held fixed, PU describes the points relative to that control, not their uncertainty in the datum, and the report says so.

Exports

Adjusted coordinates as CSV (<control name>_ADJ.csv beside your control file) and the full text report (.txt)

Adjustment report · SYN-2 exampleControlAdjust 0.2.0

Advisory review — flags are for your registered surveyor to review.

Global test
Within bounds · error factor 1.04 (expected 0.83–1.17 at 95 %)
w-tests
84 tested · 0 outside 3.29 · largest |w| 3.07
SP1 local test
2 of 84 above 1.96
Face distances
None flagged (22 pairs)
Largest change
SYN TA 3000 2.1 mm horizontally; SYN TA 1000 0.9 mm vertically
PU (control held fixed — excludes the control's own uncertainty) · 95 % · mm
PointHoriz.Vert.
SYN TA 10003.41.4
SYN TA 20003.51.1
SYN TA 30004.32.1
SYN TA 40004.51.6

Relative uncertainty (RU) between station pairs follows in the full report, with every w-test listed.

Redrawn from the ControlAdjust 0.2.0 report on the synthetic SYN-2 example network (no client data), run 5 Oct 2026.

74

field shots in the SYN-2 example that ships with ControlAdjust, recomputed to Trimble Access's own field coordinates in the self-check: largest difference 0.000 mm.

SYN-2 is synthetic data, and this is agreement between two calculations, not a field accuracy figure. Open SYN-2.jxl from the Examples folder to see the same line, then run it on a job you already know.

Write-back

Results go to a copy.

Adjusted coordinates are written into a copy of your control CSV, in your columns and your point IDs. Your original control file is never modified.

Adjusted coordinates, SYN-2 example report. Changed values are boxed, with the change in millimetres.
PointE (m)N (m)
B1011012.34565096.7820
B1021108.90125101.3450
B1031135.56805021.4567
B1041098.23404958.7654
B1051003.12344972.0090
B106985.43215040.1230
B1071121.77884987.1215
PM11045.67805005.4321
PM21078.90005062.1500
SYN TA 10001052.1389changed, +1.3 mm5031.7732changed, −0.6 mm
SYN TA 20001071.4052changed, −2.0 mm5018.3691changed, −0.4 mm
SYN TA 30001040.9041changed, −2.1 mm5049.2187
SYN TA 40001063.5509changed, −0.4 mm5044.0830changed, −0.2 mm
Results go to a copy. Your original control file is never modified.Δ is adjusted minus initial, in mm. 4 points moved; fixed control is held. The copy takes the adjusted values of the control rows you let move, plus any new marks at the end; free stations such as SYN TA 1000 stay in the report. Synthetic SYN-2 example (no client data), ControlAdjust 0.2.0.

Where it fits

Already have least squares in TBC, 12d or LISCAD?

Then you may not need this, and that's fine. ControlAdjust is a standalone, per-user licence at one published price that merges JobXML and .fld in one network and writes back to a copy of your CSV.

Trimble, Trimble Access, JobXML, TBC, 12d, 12d Model, LISCAD, STAR*NET, Windows and SmartScreen are trademarks of their respective owners, named only to identify file formats and other software. SurveyMarkup and ControlAdjust are not affiliated with or endorsed by any of them, or by ICSM.

Limits

What it doesn't do yet.

Does today

  • Yes: Least-squares adjustment of total-station control: directions, zenith angles, slope and horizontal distances
  • Yes: Trimble JobXML and 12d .fld files exported from Trimble Access, merged in one network
  • Yes: Chi-square global test and Baarda w-test (critical value 3.29 by default)
  • Yes: PU and RU computed with the ICSM SP1 formulas
  • Yes: Adjusted coordinates written to a copy of your control CSV

Not yet

  • Not yet: GNSS vectors
  • Not yet: Level runs
  • Not yet: MGA2020 checked on a real client export — pilot firms help close this
  • Not yet: Automatic AUSGeoid2020 separation outside South-East Queensland (elsewhere you enter it yourself)
  • Not yet: A code-signed installer: until then, Smart App Control, Windows S mode and some company PCs block it

Licence

The licence, in plain words.

A$495 once per user · 2 PCs

Price
A$495 once per user
Users
1 named person per licence
PCs
2 per licence
Buying
Needs an Australian mobile (confirmed by SMS); one licence per account
Activation
Once per PC, online
Check-in
Automatic and free, about once a day when you open ControlAdjust while online
Offline use
Up to 44 days after the last check-in (30 days plus 14 days' grace)
Moving PCs
Free the old PC under Your licences (up to 3 times in any 30 days; email me if you need more)
Updates
Every version released within 12 months of purchase. After that, the versions you have keep working with no further payment
After 12 months
Newer versions need a renewal, which isn't offered yet. The versions you have keep working with no further payment
If the licence server closes
I'll email every licence holder at least 90 days ahead and release an update that lets paid licences run without the check-in
Refunds
Change of mind: full refund within 30 days of purchase. Your Australian Consumer Law rights are separate and aren't limited to 30 days
Support
Email me. I aim to reply within one working day (Monday to Friday, Brisbane time, excluding Queensland public holidays). Email support is included for 12 months, the same as updates.
GST
GST not charged. SurveyMarkup is run by Tim Albash (ABN 50 427 523 590), who is not registered for GST.

Not on sale yet. Sales open after the pilot round; pilot firms run it on a real job with me first.

Install

Installing, and checking the file first.

Requirements

64-bit Windows 10 (version 1809 or later) or Windows 11, on a PC from about 2011 or later with about 200 MB of free disk space. No admin rights and nothing else to install. Internet to activate each PC, then at least once every 44 days (30 days plus 14 days' grace) for the free check-in. ControlAdjust isn't code-signed yet, so Smart App Control, Windows S mode and company policies against unsigned programs block it with no Run anyway: on a company PC, ask IT to allow it before you buy.

ControlAdjust downloads as ControlAdjust-Setup.zip (about 35 MB). Extract it, open the 'ControlAdjust Setup' folder and double-click 'Install ControlAdjust.cmd'. It checks every file against SHA256SUMS.txt, installs ControlAdjust for your Windows user (no admin rights) and runs a self-test. For a second PC, copy the whole extracted folder (USB stick, network drive or cloud link). (SHA256SUMS.txt catches a damaged copy; the SHA-256 on this page is your check that the download came from me.)

What you'll see on first install

  1. Check the download first with the PowerShell line under the SHA-256. It should print True.
  2. Right-click ControlAdjust-Setup.zip and choose Extract All. Don't run the installer from inside the zip.
  3. In the extracted 'ControlAdjust Setup' folder, double-click 'Install ControlAdjust.cmd'. If Windows shows 'Windows protected your PC', choose More info, check the app is Install ControlAdjust.cmd, then choose Run anyway.If Windows blocks it with no Run anyway, READ ME FIRST.txt explains the options under IF WINDOWS BLOCKS IT.
  4. A black window shows each step and ends with 'ControlAdjust 0.2.0 is installed' and the self-test result. Press any key to close it.
  5. Start ControlAdjust from the Start menu, paste your licence key and choose Activate. That uses one of your 2 PCs.

Unsigned build — check the SHA-256 below before you run it.

SHA-256 · ControlAdjust-Setup.zip · ControlAdjust 0.2.0

4c2ba7731c3a7d5a02f60c6e341485d5df2e8913a925b444d0f6c4491d01cd9e

Check the download in PowerShell

(Get-FileHash "$env:USERPROFILE\Downloads\ControlAdjust-Setup.zip" -Algorithm SHA256).Hash -eq "4c2ba7731c3a7d5a02f60c6e341485d5df2e8913a925b444d0f6c4491d01cd9e"

It prints True when your download matches the file I published. If it prints False, don't run it: download it again or email me. If your browser renamed the file, for example ControlAdjust-Setup (1).zip, change the name in the line.

Changelog

What changed in 0.2.0.

0.2.0 · 5 October 2026

  • Online activation: each licence runs on up to 2 PCs. ControlAdjust now connects to surveymarkup.com.au to activate a PC and checks in about once a day when online; offline it keeps working up to 44 days after its last check-in.
  • Licence dialog on first start: paste your key and choose Activate.
  • One download: a zip of about 35 MB holding the setup folder. The single-file version that runs without installing is available from me on request.

ControlAdjust questions

Not yet. Total-station control only.

Run ControlAdjust on a real job with me first.

PRICE
A$495 once
PCS
2 per user
OFFLINE
Up to 44 days
GST
Not charged

Sources

  1. 0.2.0 · 5 October 2026

    ControlAdjust release on offer and its release date

    ControlAdjust 0.2.0 was built on 5 October 2026, and it is the version I offer now; the changelog lists what changed in it.

    My decision · 11 October 2026

    Stated on: /tools/controladjust#changelog (on this page)
  2. A$495 once per user

    ControlAdjust price per user

    I set the ControlAdjust price at A$495 per user, paid once, in Australian dollars with no GST charged.

    My decision · 11 October 2026

    Stated on: /pricing#licence
  3. 1 person · 2 PCs

    People and PCs per ControlAdjust licence

    A licence is for one named person: I sell it per user and each account can hold one active licence. My licence server activates it on at most 2 PCs at a time.

    My server settings

    Stated on: /pricing#licence
  4. 44 days (30 + 14 days' grace)

    How long a bought licence keeps working offline

    Each check-in keeps a PC's activation valid for 30 days, plus 14 days' grace, so a bought licence runs up to 44 days offline after its last check-in.

    My server settings

    Stated on: /pricing#licence
  5. Windows 10 (1809+) or 11 · 200 MB

    System requirements of ControlAdjust 0.2.0

    I state these requirements in the READ ME FIRST file of the ControlAdjust 0.2.0 setup folder; the ControlAdjust README states the same Windows versions.

    My decision · 11 October 2026

    Stated on: /tools/controladjust#install (on this page)
  6. 3 months

    Length of a pilot licence

    A pilot firm's free licence runs for 3 months, with no card, no automatic charge and no obligation to buy, then stops.

    My decision · 10 October 2026

    Stated on: /pricing#pilot
  7. 13 points · largest semi-axis 4.6 mm

    SYN-2 example run: adjusted coordinates, changes, uncertainties and error ellipses

    The same SYN-2 run: adjusted coordinates in metres on the example's local origin, changes and 95 % uncertainties in millimetres, and the 95 % error ellipses, as the run's summary file and report give them.

    Sample run

    Stated on: /tools/controladjust#write-back (on this page)
  8. ellipses ×2000 · 25 m scale bar

    Drawing scales of the network plot

    The network plot draws each 95 % error ellipse 2000 times actual size so it can be seen at plan scale, with a 25 m scale bar. These are drawing scales I chose for the page, not results.

    My code

    Not public

  9. error factor 1.04 · largest w 3.07

    SYN-2 example run: global test, w-tests and statistics by observation type

    These come from one ControlAdjust 0.2.0 run on default settings over the synthetic SYN-2 example (no client data), on 5 October 2026. The page redraws the run's report; setups are named by station and start time from the example's JobXML file. The report itself isn't published yet.

    Sample run

    Stated on: /tools/controladjust#adjustment (on this page)
  10. 8 + 7 setups · 10 points

    SYN-2 example run: input files, setups, shots and control points

    The run report lists each field file with its format, version, setups and pointings, and the control file with its points; one control point is in the file but nothing observes it. It also states that a 12d field file is read on a local grid at scale factor 1.

    Sample run

    Stated on: /tools/controladjust#inputs (on this page)
  11. JobXML 5.x to 6.34

    Trimble JobXML schema versions ControlAdjust reads

    ControlAdjust reads JobXML schema 5.0 up to 6.34; a newer file is read with the 6.34 rules and a warning.

    My code

    Stated on: /tools/controladjust#inputs (on this page)
  12. 3.29 by default

    Default critical value of the Baarda w-test in ControlAdjust

    ControlAdjust flags an observation whose |w| is above 3.29 unless you change the limit in Settings; 3.29 is Baarda's limit at 0.1 % significance, and the SYN-2 report lists it under the settings used.

    My code

    Stated on: /tools/controladjust#adjustment (on this page)
  13. 74 shots · 0.000 mm

    SYN-2 example run: self-check against Trimble's field coordinates

    In the SYN-2 run, ControlAdjust recomputed Trimble Access's own field coordinates for 74 shots from the raw readings and found a largest difference of 0.000 mm. That is agreement between two calculations on synthetic data, not a field accuracy figure.

    Sample run

    Stated on: /tools/controladjust#self-check (on this page)
  14. one licence per account

    ControlAdjust licences per account

    My server sells each account one licence and refuses a second while the first is active, so each person buying needs their own account.

    My code

    Stated on: /pricing#licence
  15. about once a day

    How often ControlAdjust checks its licence while online

    ControlAdjust 0.2.0 checks in when you open it while online and its last check-in is at least 20 hours old, which comes to about once a day.

    My code

    Stated on: /pricing#licence
  16. 3 frees in any 30 days

    How often a PC can be freed under Your licences

    My licence server lets you free a PC yourself up to 3 times in any rolling 30 days; beyond that, email me.

    My server settings

    Stated on: /pricing#licence
  17. 12 months

    Updates included with a licence

    A licence includes every version released in the 12 months after purchase; the licence server records that date as one year after the licence is issued.

    My decision · 10 October 2026

    Stated on: /pricing#licence
  18. 90 days' notice

    Notice before the licence server closes

    If the licence server ever closes, I'll email every licence holder at least 90 days ahead and release an update that lets paid licences run without the check-in.

    My decision · 11 October 2026

    Stated on: /pricing#licence
  19. 30 days

    Change-of-mind refund window

    I give a full change-of-mind refund within 30 days of purchase, on top of your Australian Consumer Law rights; the refund policy has the details.

    My decision · 10 October 2026

    Stated on: /refunds
  20. one working day

    How soon I aim to reply to a support email

    I aim to reply to support emails within one working day: Monday to Friday, Brisbane time, excluding Queensland public holidays.

    My decision · 11 October 2026

    Stated on: /pricing#licence
  21. 12 months

    Email support included with a licence

    Email support comes with a licence for 12 months, the same period as updates.

    My decision · 11 October 2026

    Stated on: /pricing#licence
  22. 50 427 523 590

    Australian Business Number (ABN)

    This is my ABN as a sole trader; ABN Lookup on the Australian Business Register shows it, with the SurveyMarkup business name registered against it.

    Law or regulator · checked 19 October 2026

    Source: abr.business.gov.au/ABN/View?abn=50427523590 (external site)
  23. about 35 MB

    Download size of the ControlAdjust 0.2.0 setup zip

    I state the 0.2.0 setup zip as about 35 MB: it is 36,470,312 bytes, which Windows shows as 34.7 MB.

    My decision · 11 October 2026

    Stated on: /tools/controladjust#install (on this page)
  24. 19 free tools

    Number of free browser tools

    I count the free tools from the same tool list that builds the tools page, so the number changes when I add or retire a tool.

    My code

    Stated on: /tools